Profile Torque mode (tq)

Profile Torque mode allows the control device to transmit a Target_Torque value to the drive device, which is processed using the Torque_slope within the trajectory generator. Only linear ramp (trapezoidal profile) is supported. This mode can only be used if Closed Loop modality is active.

Related objects:

Index Object Name Type Attr. M/O

6040.0H

VAR

Controlword

UNSIGNED16

rw

M

6041.0H

VAR

Statusword

UNSIGNED16

ro

M

6071.0H

VAR

Target_Torque

INTEGER16

rw

M

6072.0H

VAR

Max_Torque

UNSIGNED16

rw

O

6074.0H

VAR

Torque_demand

INTEGER16

ro

O

6077.0H

VAR

Torque_actual_value

INTEGER16

ro

M

6078.0H

VAR

Current_Actual_Value

INTEGER16

ro

O

6087.0H

VAR

Torque_slope

UNSIGNED32

rw

M

2230H

ARRAY

Closed Loop

INTEGER32

rw

O

2005.4H

VAR

Nominal_Current

UNSIGNED16

rw

M

2B08.0H

VAR

Torque_window

UNSIGNED16

rw

O

2B09.0H

VAR

Torque_window_time

UNSIGNED16

rw

O